AckleySipes929

kalapediasta
Tämä on arkistoitu versio sivusta sellaisena, kuin se oli 10. kesäkuuta 2021 kello 16.42 käyttäjän 162.158.94.179 (keskustelu) muokkauksen jälkeen. Sivu saattaa erota merkittävästi tuoreimmasta versiosta.
(ero) ← Vanhempi versio | Nykyinen versio (ero) | Uudempi versio → (ero)
Siirry navigaatioon Siirry hakuun

Pal3 Autosampler, Strong Part Extraction

Dual X-rails and large-diameter Z-rail provide exact sampling, virtually eliminating missed samples–even on microplates. Category Description Status Necessary These cookies are answerable for the provision of crucial web site functionalities, e.g. for saving information safety and content material settings. They also enable us to measure and aggregate nameless user conduct knowledge to enhance our website. We wish to point out that in relation to particular person cookies and repair suppliers, your information is processed within the USA.

Check that both air gaps are exterior the pattern loop verify rotor seal rotor seal could be taken out without using tools by unscrewing the seal holder in the center of the valve by hand. Do not touch the hex nut in the middle of the seal holder.This is used to adjust the spring pressure that keeps the seal in place. For dynamic and steady evaluation of the head-space of a vial, the autosampler is equipped with an extra holder to mount the heated inlet hose from the PTR-MS. This permits to attach the PTR-MS inlet capillary to the outlet port of a double needle adapter. The sampling vial is transported to a specific tray place near the heated hose and subsequently penetrated using the double needle adapter.

For prolonged autocampionatore spazio di testa productivity, the system can operate two injectors concurrently by way of its Gemini configuration. A broad vary of the very best high quality vials and closures with innovations that ensure pattern cleanliness, safety, and integrity in a wide selection of methods. Internal standard addition, pattern dilution, or derivatization steps are simply programmed to cut back sample preparation time and errors associated with manual procedures. The autosamplers could be configured in a extremely variable method and adjusted to most diverse purposes. The design may be matched to the respective analyser the autosampler is coupled to.

This series can additionally be designed with removable sample trays for straightforward switching between operating aqueous and natural matrices. The autosampler can be used in numerous analytical methods (AAS, TOC, FIA and so forth.). Another subject of utility of the autosamplers is sampling and pattern preparation. H-Sampler™ automation software helps rack and test mattress customization, experiment design for library production or course of optimization and full management of the liquid handler and the H-Cube® Pro.

Everything is integrated; you don’t want extra software to control and run the autosampler. The operation may be very intuitive and user-friendly – a measurement cycle is set up within a couple of minutes and may be repeated with just one mouse-click. Process extra samples, rapidly, while enhancing the consistency and high quality of your GC knowledge. This rugged, easy-to-use GC liquid autosampler is out there as the 8-position AI 1310 autoinjector and the 155-sample capacity AS 1310 autosampler.